কোল্ড জংশন তাপমাত্রা ক্ষতিপূরণ হল হট রানার থার্মোকলের দীর্ঘ-দূরত্বের সঠিক তাপমাত্রা পরিমাপ নিশ্চিত করার জন্য মূল সহায়ক প্রযুক্তি। থার্মোকল দ্বারা উত্পন্ন থার্মোইলেকট্রিক সম্ভাব্য গরম প্রান্ত এবং ঠান্ডা প্রান্তের মধ্যে তাপমাত্রার পার্থক্য দ্বারা সরাসরি প্রভাবিত হয়। In actual production, the cold end connected to the temperature control terminal cannot always be kept at the standard zero-degree reference temperature, and the change of workshop ambient temperature will cause the cold end temperature to fluctuate continuously, resulting in inherent systematic errors in temperature measurement data. Scientific and standardized use of cold junction compensation technology can effectively eliminate such reference temperature errors and make the detected temperature data infinitely close to the real working temperature.
At present, the most widely used in the injection molding industry is the automatic cold junction compensation function built into the temperature controller. This mode is equipped with a high-sensitivity ambient temperature sensing element inside the temperature control box, which can monitor the real-time temperature of the cold junction connection position in real time. According to the detected actual cold junction temperature value, the system automatically calculates the temperature error value generated by the reference temperature deviation, and superimposes the compensation value on the original temperature feedback signal, so as to correct the deviation data and realize automatic error correction without manual repeated adjustment by technicians. This compensation method has the advantages of simple operation, real-time response and strong follow-up performance, and is suitable for most conventional hot runner production equipment with stable wiring layout.
In the actual use process, to ensure that the automatic compensation function gives full play to its effect, the installation position of the temperature control box must be reasonably arranged first. It is necessary to place the temperature control equipment in a ventilated and cool position away from high-temperature heat sources such as hot runners and heating furnaces, avoid direct baking of high-temperature heat flow causing local overheating of the cold junction, and also prevent direct blowing of cold air from workshop air conditioners and fans, resulting in sudden drop of cold junction temperature and unstable compensation benchmark. Keep the ambient temperature around the terminal box relatively stable, so that the built-in temperature sensing element can accurately capture the real cold junction temperature, and ensure the accuracy of automatic compensation data.
The standard matching of compensation wires is another key link to ensure the effect of cold junction compensation. Special thermocouple compensation wires have the same thermoelectric property trend as the internal wire core of thermocouples, which can extend the cold end from the high-temperature mold side to the stable temperature control box side, and offset the temperature error generated in the extension section. In the process of wiring and replacement, it is strictly forbidden to use ordinary high-temperature wires or non-matched models of compensation wires instead. Different types of thermocouples must be matched with corresponding special compensation wires, and ensure that the positive and negative pole wiring is consistent and the wire specifications are unified, otherwise it will directly cause compensation failure and expand temperature measurement deviation.
For some old-fashioned temperature control equipment without automatic compensation function, manual fixed value compensation mode needs to be adopted. According to the average ambient temperature of the production workshop in different seasons, manually set the corresponding cold junction compensation value inside the controller. In winter when the temperature is low, appropriately reduce the compensation parameter value, and in summer when the temperature is high, increase the compensation value in a targeted manner, and regularly compare and calibrate the actual temperature to adjust the compensation parameters in time, so as to keep the temperature measurement error within the qualified range.
প্রতিদিনের কাজে ঠান্ডা সংযোগ সংযোগের অবস্থান নিয়মিত পরিদর্শন করুন এবং বজায় রাখুন, টার্মিনাল সংযোগটি আঁটসাঁট এবং পরিষ্কার রাখুন, যোগাযোগের পয়েন্টগুলিতে ধুলো এবং অক্সাইড জং অপসারণ করুন, ক্ষতিপূরণ সংকেতগুলির স্থিতিশীল সংক্রমণকে প্রভাবিত করে দুর্বল যোগাযোগ এড়ান এবং নিশ্চিত করুন যে ঠান্ডা জংশন ক্ষতিপূরণ সিস্টেম দীর্ঘ সময়ের জন্য স্থিতিশীলভাবে চলে। কোল্ড জংশন ক্ষতিপূরণ প্রযুক্তির সঠিক ব্যবহারের নিয়মগুলি আয়ত্ত করা থার্মোকলের অন্তর্নিহিত পরিমাপের নির্ভুলতাকে সর্বাধিক করতে পারে, প্রযুক্তিগত স্তর থেকে পদ্ধতিগত তাপমাত্রার ত্রুটিগুলি দূর করতে পারে এবং পরিশোধিত ইনজেকশন ছাঁচনির্মাণ প্রক্রিয়া উত্পাদনের জন্য আরও সঠিক এবং নির্ভরযোগ্য তাপমাত্রা ডেটা সহায়তা প্রদান করতে পারে।